REHABBED 6 TON LEG MOUNTED CO2 RECEIVER
|
Includes: clean
and inspect internally, remove
sheet metal from sides, check and repair insulation as needed,
recover sides with prepainted white aluminum sheets, repaint heads and leg
supports, install new 1.5 HP Copeland R-404A refrigeration
unit with all new refrigeration line components. Cutler Hammer electrical panel
with fused disconnect, motor starter, control voltage
transformer, Allen Bradley pressure switch and all other
components necessary for automatic operation, new single bleeder, new dual
ASME safeties (sized for outdoor installation), new Jamesbury
(Eliminator) stainless steel ball valves installed on one each 1” vapor balance and
1.5” liquid fill lines (w/new CGA fittings and 1/2" hose blow-down
valves), 1” vapor and 1” liquid process lines and three ½”
instrument isolation valves, rebuilt Barton liquid level
indicator, new 6" 0-600 psi pressure indicator, fabricate
small cover over the
refrigeration unit and complete check out with all controls
set for proper operation.
Vessel Serial Number #19321 (516
steel)
|
|
|
REHABBED 13 TON CARDOX
|
Includes: Clean and inspect internally, check
insulation, cover sides using pre-painted white aluminum
sheets with a new carbon steel bottom section, repaint front
and rear heads, install new 2 HP Copeland R-404A refrigeration
unit with all new refrigeration line components, Cutler Hammer electrical panel
with fused disconnect, motor starter, control voltage
transformer, Allen Bradley pressure switch and all other
components necessary for automatic operation, new dual bleeders, new dual
ASME safeties (sized for outdoor installation), new Jamesbury
(Eliminator) stainless steel ball valves on one each 1" vapor balance and
1.5" liquid fill lines (w/new CGA fittings and hose blow-down
valves), 1" vapor and 1" liquid process lines and three 1/2"
instrument isolation valves, rebuilt Barton liquid level
indicator and new 6" 0-600 psi pressure indicator. Complete check out
with all controls set for proper operation.
National Board #43974
(515 steel)
|
|
|

REHABBED 14 TON SKID MOUNTED CO2 RECEIVERS
Includes: Clean and inspect internally, remove sheet metal
from sides, check and repair
insulation as needed, recover sides with pre-painted white aluminum sheets,
repaint heads, install new 2 HP Copeland
R-404A refrigeration unit with all refrigeration new line
components, Cutler Hammer electrical panel
with fused disconnect, motor starter, control voltage
transformer, Allen Bradley pressure switch and all other
components necessary for automatic operation, new dual
bleeder, new dual ASME safeties (sized for outdoor
installation), new Jamesbury (Eliminator) stainless steel ball
ball valves installed on 1
each vapor 1" vapor balance and 1.5" liquid fill lines (w/new CGA
fittings and 1/2" hose blow down valves), 1" vapor and 1"
liquid process lines and 3 1/2" instrument isolation valves,
rebuilt Barton liquid level indicator, new 6" 0-600 psi pressure indicator,
recover control cabinet frame with prepainted white aluminum sheets
with new stainless steel hinge and lockable door. Complete check out with all controls set
for proper operation.
National Board #11 (612 steel) #3661
(612 steel) #10871 (515 steel) In addition
refurbished 12 ton skid mounted CO2 Receiver - NB#645
(212 steel)
|
|
|
|
|

REHABBED 50 ton horizontal CO2 receiver
BUILT BY LUBBOCK FOR LIQUID CARBONIC
|
Price Includes: Clean and inspect internally, remove sheet metal
from sides, check and repair insulation as needed, recover sides
with prepainted white aluminum sheets, repaint heads, new modular 6HP Copeland R404A refrigeration unit with all new
line components, Cutler Hammer electrical panel with fused
disconnect, motor starter, control voltage transformer, Allen
Bradley pressure switch and all other components necessary for
automatic operation, new dual bleeders, new dual ASME safeties (sized for
outdoor installation), new Jamesbury (Eliminator) stainless steel ball
valves installed on 1" each vapor balance and 1.5" liquid fill lines w/CGA
fittings and 1/2" hose blow-down valves, and 1" vapor and 1" liquid process
lines and three 1/2" instrument isolation valves, rebuilt existing Barton
liquid level indicator, new 6" 0-600 psi pressure indicator. Complete check out
with all controls set for proper operation. NOTE: 280PSI MAWP
National Board #2040 (515 steel)
NOTE: The price includes testing the refrigeration system, instruments and all valves with
liquid carbon dioxide in the vessel for a minimum of 48 hours.
After testing, the refrigeration charge (R-404A) will be pumped into
the reservoir and sealed off. The lines will be cut and capped
for shipment. Connecting the system on site will be done by
others and requires connecting all lines, pulling a vacuum on all
lines, opening the service valves to release the charge, monitoring
the system during the first few cycles to insure everything is
running perfectly. Some fine tuning may be required as actual
conditions may differ from test conditions. If this work is
not done properly it could result in problems that are beyond our
control. Therefore, it should only be performed by a qualified
refrigeration technician. |
|

Rehabbed 50 ton
skid mounted CO2 receivers
Price includes: Clean and inspect internally, remove sheet
metal from sides, check and repair insulation as needed,
re-cover sides with pre-painted white aluminum sheets, repaint
heads, install new 6 HP Copeland R-404A refrigeration unit
with all new refrigeration line components, Cutler Hammer
electrical panel with fused disconnect, motor starter, control
voltage transformer, Allen Bradley pressure switch and all
other components necessary for automatic operation, new dual
bleeders, new dual ASME safeties (sized for outdoor
installation, new Jamesbury "Eliminator" stainless steel ball
valves installed on one each 1" vapor balance and 1.5" liquid
fill lines w/new CGA fittings and 1/2" hose blow down valves,
1" vapor and 1" liquid process and 3 ea. 1/2" instrument
isolation valves, rebuilt Barton liquid level indicator, new
6" 0-600 PSI pressure indicator, recover control cabinet frame
with prepainted white aluminum sheets with new stainless steel
hinge and lockable door. Complete check out with all
controls set for proper operation.
NB: 30 (612 steel) and NB: 13057 (516
steel)
|
|
PLEASE NOTE:
Pictures show basic style of
receivers offered. Actual receivers may vary slightly in appearance. All receivers tested before shipment with all controls set for proper
operation. Vaporizers not included unless noted, but are available.
All receivers are FOB Monroe, GA. and are subject to prior sale and availability. Data reports
normally available upon request.